Buying guide
A log burner gives you a real fire you can control: dry wood burns slowly behind glass, the stove body soaks up the heat and passes it into the room for hours. Get three things right and the rest is down to taste: the output for your room, the flue you have to connect to, and the rules where you live. This guide walks through each one, with the stoves we would look at first.
What is a log burner?
A log burner, or wood burning stove, is a closed firebox of steel or cast iron with a glass door, a flue outlet and adjustable air controls. Because the fire is sealed in and the air supply is controlled, the wood burns far more completely than on an open grate, and more of its heat stays in the room instead of rushing up the chimney. Modern stoves also feed preheated air across the inside of the glass (often called airwash) and above the fire, which burns off more of the smoke and keeps the window clearer.
The stoves on this page fall into two groups. Wood-only stoves, such as the Opus and Woodfire ranges and the Carron ECO Revolution, burn logs on a bed of ash, which is how wood likes to burn. Multi-fuel stoves, such as the FDC Eco and Woolly Mammoth stoves, add a riddling grate and ash pan so they can also burn approved smokeless fuel. The Carron ECO 5kW sits in between: it is a wood stove that converts to multi-fuel with Carron's kit. If you want the choice of fuels, see our multi-fuel stoves.
Efficiency figures on our product pages are the manufacturer's, and most of our log burners are rated between about 76% and 86%. The Carron ECO Revolution 5kW is rated at 82.7%, the FDC4 Eco at 81.8% on wood and the Opus Harmony at 80%.
What size log burner do you need?
The output of a stove is quoted in kilowatts (kW). As a starting point, allow about 1kW for every 14 cubic metres of room volume in an average room. Measure length x width x ceiling height in metres, divide by 14, and choose the stove with the nearest nominal output.
A living room 5m long and 4m wide with a 2.4m ceiling is 48 cubic metres. Divided by 14 that is about 3.4kW, so a 4kW or 5kW stove suits it. The same room in a Victorian terrace with a 3m ceiling and original sash windows is 60 cubic metres and loses heat faster, so a 5kW stove is the safer choice there.
| Room (2.4m ceiling) | Volume | Rule of thumb | Stoves to look at |
|---|---|---|---|
| 3.5m x 3.5m snug | 29m³ | About 2kW | Our smallest: the 4kW FDC4 Eco, which turns down to about 3kW |
| 5m x 4m living room | 48m³ | About 3.4kW | 4kW to 5kW: Carron ECO 5kW, Opus Aria D |
| 6m x 5m living room | 72m³ | About 5kW | 5kW: Carron ECO Revolution 5kW, FDC5W Eco |
| 7m x 5m room | 84m³ | About 6kW | 6kW to 7kW: Opus Harmony LS |
| 8m x 6m open plan | 115m³ | About 8kW | 8kW: Carron ECO Revolution 8kW, FDC8 Eco |
Rooms with solid walls, single glazing, high ceilings or an open staircase need more heat; a modern extension or a well insulated new build needs less. The rule of thumb gets you into the right range, and a heat loss check by your installer gives the right answer for your house. Our guide to what size stove you need has more worked examples.
Bigger is not better. An oversized stove overheats the room, so it gets run with the air turned right down. A starved fire smoulders, blackens the glass, tars the flue and wastes wood. Choose a stove you can run at a lively burn most evenings.
The 5kW figure matters for another reason. In England, Approved Document J does not normally ask for a permanent air vent for a stove rated at 5kW or less in a home built before about 2008, because older houses are leaky enough to feed it. Above 5kW, or in an airtight newer home, a vent is needed. That is why so many people choose a 4kW or 5kW stove. Our guide to air vents for log burners explains the sums.
Types of wood burning stove
Most people want a freestanding stove on a hearth, either in the old fireplace opening or standing in the room. There are three other layouts worth knowing about.

Best for most rooms
Freestanding stoves
Stand on a hearth in a fireplace recess or out in the room, connected by stove pipe to a lined chimney or twin wall flue. The widest choice of sizes and styles.

Built into the wall
Inset stoves
Sit flush in a builder's opening for a clean, fireplace look. Ours are Woodfire inset boiler stoves that also heat radiators and hot water.

Heats the house
Boiler stoves
A water jacket sends part of the heat to your central heating or hot water cylinder. Designed with a heating engineer as part of the system.

Two rooms, one fire
Double sided stoves
Glass on both faces, built into a wall between two rooms or into a central chimney, so both spaces see the flames.
How to choose a log burner
Once you know the output, work through this list before you fall for a particular look. Most of these points are on each product page; if one is missing, ask us before you order.
- Flue outlet size. The Carron, FDC and Woolly Mammoth stoves here have a 125mm (5 inch) outlet, Opus and the freestanding Woodfire stoves 150mm, and the Woodfire inset stoves 200mm. Your liner or flue must be at least the size of the outlet.
- Top or rear outlet. A rear outlet lets a stove sit further back into a recess. Many of ours take either; the Carron ECO 5kW, Opus Calypso and the Woodfire CX and EX stoves are top outlet only.
- Smoke control area. If you live in one and want to burn wood, the stove must be exempt. Check your council's map first.
- Log length. Compact stoves take logs of about 250mm to 300mm; the FDC5W and FDC8 take about 375mm, the Woolly Mammoth 8 up to 400mm and the Woodfire Panorama models 600mm. Shorter logs mean more splitting.
- Clearances and hearth. Every manual gives distances to combustible materials and the hearth size. A stove with small clearances fits a tight recess or a room with a timber beam.
- Weight. Stoves here run from about 50kg to over 250kg. Heavy stoves need a sound floor and a plan for getting them into the room.
- External air. In an airtight home, a stove that can take its combustion air straight from outside (the Carron ECO 5kW has a 95mm spigot, and Opus offers an external air kit) avoids competing with extractor fans.
- Looks and glass. Wide windows show more fire. Cast iron gives a traditional finish; welded steel suits a contemporary room.
Our picks
These are the stoves we point most people towards first, chosen on output, efficiency and how easy they are to live with.
For a typical living room. The Carron ECO 5kW is a cast iron stove rated at 78.6% efficiency, approved for smoke control areas, with a 125mm top flue and a 95mm external air spigot. It comes in matt black or six enamel finishes and converts to multi-fuel with a kit. Its steel-bodied sister, the Carron ECO Revolution 5kW, is rated at 82.7% with a top or rear flue. If you prefer a tall, contemporary shape with a log store underneath, the Opus Melody LS is a 5kW cylindrical stove on a 150mm flue.
For bigger and open plan rooms. The Carron ECO Revolution 8kW and the multi-fuel FDC8 Eco both keep the 125mm flue and smoke control exemption at 8kW. The Opus Harmony GLS gives 7kW with a full glass door and log store, and the Harmony PR sits on a pedestal that rotates so you can turn the fire towards you.
For heating the house. If you want the stove to run radiators or heat water, look at the boiler stoves, from the 8.3kW Opus Calypso to the Woodfire inset range.
Smoke control areas and Ecodesign
Two sets of rules get mixed up, and they mean different things.
Ecodesign is the efficiency and emissions standard for new stoves. Since 1 January 2022, wood and multi-fuel stoves placed on the market in Great Britain must meet it, with limits on particulates, carbon monoxide, nitrogen oxides and organic gases and a minimum seasonal efficiency. It applies to the stove when it is sold, not to stoves already in homes. The log burners here are Ecodesign models; browse them all in Ecodesign stoves.
Smoke control areas cover many towns and cities across the UK; your council can tell you if you live in one. In one, you must not let smoke come from your chimney, and wood is not an authorised fuel. You can burn wood only in a stove that is exempt (on Defra's list of exempt appliances), using the fuel and settings its exemption covers. Councils can issue penalties for smoky chimneys. Stoves we list as exempt include the Carron ECO 5kW, both ECO Revolution stoves, all four FDC Eco stoves and the Woolly Mammoth stoves. See smoke control approved stoves.
Opus makes SE versions of some of its stoves for smoke control areas; check the options on the listing or contact us before you order. Wales, Scotland and Northern Ireland have their own lists and rules. For what is proposed next, read are wood burners being banned? (the short answer is no).
Installation, flue and hearth
A wood burning stove is building work under the Building Regulations. In England and Wales, the simplest route is a HETAS registered installer, who designs the installation, fits it, self-certifies it and notifies your council. If you use anyone else, you must involve your council's building control before the work starts. Keep the certificate: insurers and buyers ask for it.
Your installer works to Approved Document J and the stove manual. The points that most often affect what you buy:
- Flue size. Approved Document J allows a 125mm flue for a stove up to 20kW that is exempt for burning wood in smoke control areas; other stoves up to 30kW need at least 150mm. The flue must never be smaller than the stove's outlet.
- The chimney. Old chimneys built for open fires are much wider than a stove outlet, so most installers fit a flexible stainless steel liner sized to the stove. With no chimney, a twin wall insulated flue can run through the roof or up an outside wall: see installing a wood burner without a chimney.
- Stove pipe. Inside the room, single wall stove pipe connects the stove to the chimney. A horizontal run from a rear outlet should not exceed 150mm, bends should be no more than 45 degrees from vertical, and bare pipe needs a set distance (or a shield) from anything combustible.
- Hearth. If the maker confirms the stove cannot heat the floor beneath it above 100°C, it can stand on a non-combustible plate at least 12mm thick, such as our glass and granite hearths. Otherwise it needs a 125mm constructional hearth. The non-combustible zone usually extends 225mm in front and 150mm at the sides; the manual has the exact figures.
- Carbon monoxide alarm. A new or replacement stove needs a CO alarm to BS EN 50291-1 in the same room, between 1m and 3m from the stove, such as the SleepSafe COA10 with its sealed 10 year battery.
Not sure what flue you have? Our guide to chimney and flue options shows how to tell, and how tall your chimney should be covers the height rules.
Fuel, lighting and looking after it
Dry wood is the single biggest thing you control. Logs should be under 20% moisture: wet wood spends its energy boiling off water, smokes, blackens the glass and coats the flue with tar. In England, wood sold in quantities under 2 cubic metres must carry the Ready to Burn mark, which confirms 20% or less. If you season your own, split it, stack it off the ground under cover with the sides open, and check it with a moisture meter. Our firewood guide compares the common UK woods.
Light with the top-down method: two or three logs at the bottom, kindling across them, a natural firelighter on top, all air controls open. Once the stove is hot, turn the air down to a steady, lively flame rather than a smoulder. Our step by step guide on how to light a log burner covers the first few fires, when the paint on a new stove cures and gives off a smell.
Fire and rescue services recommend sweeping the chimney quarterly while you burn wood regularly, and at least once a year for smokeless fuel. A yearly service checks the door rope, glass seal, firebricks and baffle, which are the parts designed to wear. Wood likes a thin bed of ash, so only take out the excess. See our log burner maintenance checklist, and if something is not right, common stove problems and fixes.
Common questions
What size log burner do I need?
Multiply the room's length, width and ceiling height in metres, then divide by 14. A 48 cubic metre living room comes out at about 3.4kW, so a 4kW or 5kW stove. Older, draughty rooms need more and new, insulated rooms less; your installer's heat loss check gives the final answer.
Do I need an air vent for a 5kW log burner?
In England, not normally in a home built before about 2008, as long as the stove's rated output is 5kW or less. Airtight newer homes need 550mm² of permanent vent for every kW of output, and some manufacturers ask for a vent regardless.
Can I install a log burner without a chimney?
Yes. A twin wall insulated flue can run up through the house and roof or out through a wall and up the outside. It must meet the same Building Regulations as a chimney for height, outlet position, bends and clearances.
Which log burners can I use in a smoke control area?
Only stoves exempt for smoke control areas, burning the fuel their exemption covers. Ours include the Carron ECO 5kW, both Carron ECO Revolution stoves, the FDC4, FDC5, FDC5W and FDC8 Eco and the Woolly Mammoth stoves.
What is the difference between a wood burner and a multi-fuel stove?
A wood burner burns logs on a flat bed of ash. A multi-fuel stove adds a riddling grate and ash pan so air can reach smokeless fuel from below, letting it burn either wood or approved smokeless fuel.
What flue size does a log burner need?
At least the size of its outlet, which is 125mm on our Carron, FDC and Woolly Mammoth stoves and 150mm on Opus. Approved Document J allows 125mm for stoves exempt for burning wood in smoke control areas and asks for 150mm for other stoves up to 30kW.
Do I need a hearth for a log burner?
Yes. If the manufacturer confirms the stove cannot heat the floor beneath it above 100°C, a non-combustible plate at least 12mm thick is enough. Otherwise you need a 125mm constructional hearth. The manual gives the size.
Who can install a wood burning stove?
In England and Wales, a HETAS registered installer can fit it and self-certify the work to Building Regulations; anyone else must notify building control before starting. In Scotland and Northern Ireland, your council's building standards or building control rules apply. A carbon monoxide alarm is required in the room.
Are wood burners being banned?
No. You can still buy, install and use a wood burner in England. New stoves must meet Ecodesign, and in a smoke control area you need an exempt stove to burn wood.
How often should a log burner chimney be swept?
Fire and rescue services recommend quarterly while burning wood regularly and at least once a year for smokeless fuel, with a service of seals and firebricks each year.
Find the right log burner
Most living rooms suit a 4kW or 5kW stove. Compare them side by side, or ask us about any stove's specification before you order.